Retired - DRE Signal NIBP & Pulse Oximetry Monitor

Model Number:
66700
Condition:
  • Retired
download sales sheetSales Sheet
More Resources
Manuals, Docs, Links
Retired - DRE Signal NIBP & Pulse Oximetry Monitor

Product Description

FEATURES

  • High resolution 6.5” (diagonally) monochrome LCD display
  • 24 hours data storage facility in graphical mode with zoom facility and separate tabular trend for 100 NIBP readings
  • NIBP with three modes: Manual, Automatic, STAT
  • Graded and color coded audio/visual alarms
  • Alarm recall facility to view last 16 critical alarms (patient related)
  • Rechargeable battery backup
  • External battery jack (12V) for car battery – Transport application
  • Can be used as transport and ambulatory monitor
  • Suitable for neonate, pediatric, and adult applications
  • Optional Printer

SPECIFICATIONS

Non-Invasive Blood Pressure
Oscillometric Principle, Display of Systolic, Diastolic and Mean pressure

  • Modes: Manual, STAT (5min continuous), Automatic (interval 2 min. to 90 min.)
  • Range: 20 to 255mmHg
  • Auto Zero: Zero Pressure Reference is automatically established after every reading
  • Cuffs: Quick Connect/Disconnect
  • Safety Features: Automatic deflation if - pressure exceeds 300 mmHg for adult and 150 mmHg for neonate – Measurement time exceeds 180 seconds (adult) 90 seconds (neonate) – microprocessor failure.
  • Alarm limits: Selectable for Systolic and Diastolic
  • Range: 20-250+mmHg
  • Accuracy: +/-3 mmHg

Pulse Oximetry
Pitch variation with change in oxygen saturation.

  • SpO2 range: 0 - 100%
    Display of pulse strength, plethysmograph, PR and SpO2 values.  Display of perfusion on bar graph
  • Accuracy: 100 to 70 % (+/- 2 digits ), 69 to 50 % (+/- 3
    digits ), 49 to 0 % (unspecified) Accuracy in
    neonatal monitoring 100 to 70% (+/- 3 digits)
  • Modes: Normal and Fast Response
  • Alarms: Low 50-95% - High 55-100%

Alarms
Alarm setting for all parameters.

  • Patient alarm: RED flashing with audio and message indicator
  • Equipment alarm: YELLOW flashing with audio and message
    indicator. Alarm auto-set facility provided Auto setting of alarm for PR and SpO2.
  • Manual settings: Systolic and Diastolic
  • Alarm Recall: Last 16 critical alarms with time and date Volume control: 4 levels of volume Trends 24 hr. of Graphical and Tabular trend for HR/PR, SpO2
  • NIBP trend: Last 100 readings (tabular)
  • Alarm Recall: Last 16 alarm events with date, time and message. 2hr. zoom for graphical trends with mark, record and print facility.
  • Time Scale: 12 Hr. (resolution of 3 min) and 2 hr (resolution 30 Sec) for graphical trend Recording Optional in-built dual channel thermal recorder for recording two waveforms (selectable) with numerical data and alarm
    status. NIBP and tabular trend recording with patient information. Direct / Delayed / Continuous modes of recording. Record On Alarm facility (selectable)
  • Speed: 25 mm/sec or 50 mm/sec

Dimensions

  • General Dimension: 145 X 220 X 185 mm (H X W X D)
  • Weight: 3.5 kg. with in-built battery and recorder.

Power Supply

  • Universal power supply: 95-265V AC, 50 / 60 Hz
  • Power ratings: 40 Watt
  • Battery type: 14.8V, 14.4Ah (Li-ION)
  • Operating time: 4 hours on fully charged battery (with full load & NIBP auto mode 2 mins. interval & recorder on for 2 mins.)
  • Charging time: 100% charge in 6 hr. for fully discharged battery
  • External Battery: 12V DC input

Display

  • Resolution: 640 x 480 pixels
  • Type: Color
  • Size: 6.4”

Back Panel

  • VGA output
  • Mains power on/Off
  • RS-232 Output
  • Ground Connection
  • External Printer Port

Trace Speed

  • 12.5, 25 or 50mm/sec
TOP^