Superior performance with a high-resolution touch-screen

The DRE Waveline Pro displays as many as eight colorful waveforms on a crisp, high-resolution 15-inch touch-screen that optimizes the speed of patient care. The user can make quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data. Designed for a fast paced work environment, the Waveline Pro patient monitor offers an extremely simple and adaptable user interface. Patient information along with vital-signs settings can be quickly modified to meet the needs of a patient's changing condition, converting from a basic vital signs monitor, to a continuous bed side monitor, to an operating room monitor. 

This patient monitor offers standard measurements of: non-invasive blood pressure, 3-lead or 5-lead ECG with arrhythmia detection, motion tolerant SpO2, Temperature, and Respiration rate. End-tidal CO2, Anesthetic Agent measurement, Cardiac Output and Invasive blood pressure are available options. 

The Waveline Pro monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a HL7-based hospital information system. It offers Ethernet and RS-232 connections with an open source communication protocol, and it is HL7 compliant. The HL7 network protocol will allow for all patient information and vital sign trends to be transferred and stored on a hospital information system. 

Capnography is outpacing Pulse Oximetry as the new standard of care in outpatient surgery procedures. Click to see the dramatic difference between CO2 and SPO2.

FEATURES:

  • Optional Integrated Drager Anesthesia Gas Bench expands measurement capabilities
  • Optional agent bench is compact and part of main unit.  All in one monitor!
  • Large (15”), touch-screen with high-resolution flat panel display
  • Displays as many as eight waveforms
  • Multi-lead simultaneous ECG monitoring
  • Automatically set alarm limits
  • Graphical and tabular trending
  • Color-coded alarms
  • Patient data entry
  • Networking capability
  • Works with EMR and wireless telemetry systems
  • Large time stamp in upper right corner
  • Standby button
  • Volume and Sounds are adjustable and can be turned off completely
  • Option to print Numerical Data Only
  • Color of the waveforms can be changed
  • Battery backup (two removable batteries)
  • Available with a built-in thermal printer

SPECIFICATIONS:

Peformance 
  • Display: 15-inch color touch-screen
  • Trace: 8 waveforms
  • Indicator: 
    • Alarm indicator
    • Power indicator
    • QRS beep and alarm sound
  • Trend time: 1 - 72 hour
  • Recorder: 
    • Built-in, thermal array, 3 channels
    • Record width: 48mm
    • Recorder paper: 50mm
    • Record speed: 25mm/s, 50mm/s
ECG
  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range: 30 ~ 300bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: 
    • upper limit 100 ~ 200bpm,
    • lower limit 30 ~ 100bpm
RESP
  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: 
    • upper limit 6 ~ 120 rpm,
    • lower limit 3 ~ 120 rpm
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
NIBP
  • Measuring Technology: automatic oscillating measurement
  • Cuff Inflating: <30s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
  • Pulse Rate Range: 30 ~ 250 (bpm)
  • Measuring Range:
  • Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg)
  • DIA :15 ~ 200 (mmHg)
  • Neonatal Mode: SYS: 40 ~ 135 (mmHg)
  • DIA : 15 ~ 100 (mmHg)
  • Accuracy:
    • Maximum Mean error: ±5mmHg
    • Maximum Standard deviation: 8mmHg
TEMP
  • Range: 25 ~ 50 (°C)
  • Accuracy:
    • ± 0.2°C (25.0 ~ 34.9°C)
    • ± 0.1°C (35.0 ~ 39.9°C)
    • ± 0.2°C (40.0 ~ 44.9°C)
    • ± 0.3°C (45.0 ~ 50.0°C)
  • Display Resolution: 0.1°C
  • Alarm Limit Setting:
    • upper limit 0 ~ 50°C,
    • lower limit 0 ~ 50°C
  • Channel: 2 channels

SpO2
  • ASpO2: Anti-motion SpO2
  • SpO2% Range: 0-100%
  • SpO2 Accuracy: 
    • ±2% (70 ~ 100%, non-motion)
    • ±3% (70 ~ 100%, motion)
  • Pulse Rate Range: 30-250 bpm
  • Pulse Rate Accuracy: 
    • ±2 bpm (non-motion
    • ±3 bpm (motion)
  • Alarm Limit Setting: 
    • upper limit 70 ~ 100%,
    • lower limit 70 ~ 100%
  • SpO2 Probe: 
    • Red light LED wavelength
    • 660nm±5nm
    • Infrared light LED wavelength
    • 940nm±10nm
IBP
  • Measurement Range: -50 ~ 300mmHg
  • Channel: 2 channels
  • Pressure Transducer: sensitivity, 5µV/V/mmHg
  • Impedance Range: 300 ~ 3000Ω
  • Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1mmHg
  • Accurancy: ±1mmHg or ±2%,whichever is greater
  • AlarmRange: -10 ~ 300mmHg
EtCO2 (Optional)
  • CO2 Measurement Range: 0 ~ 99mmHg
  • Accuracy: 
    • ±2mmHg (0 ~ 38mmHg)
    •  39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes.
  • Respiration Rate: 0 ~ 150 breaths/min
  • Mode: adult, neonate
Cardiac Output (Optional)
  • Measurement Method: Thermodilution Method
  • CO2 Measurement Range:
    • C.O.: 0.1 to 20 L/min
    • TB: 23 to 43
    • TI: 0 to 27
  • Resolution: 
    • C.O.: ±5% or ±0.1 L/min, whichever is greater, as measured using electornically generated flow curves.
    • TB, TI: 0.1
  • Accuracy: 
    • ±5 or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.
    • TB, TI ±0.1 (without sensor)
  • Alarm Range: TB 23 to 43
  • Repeatability: C.O. ±2% or 0.1 L/min, whichever is greater, as measured using electronically generated flow curves.

Anesthetic Agents (Optional)

  • Method: Infrared absorption
  • Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
  • Measurement Range:
    • Halothane, Isoflurane: 0 – 8.5%
    • Enflurane, Sevoflurane: 0 – 10%
    • Desflurane: 0 – 20%
    • CO2: 0 – 10%
    • N2O: 0 – 100%
    • O2: 0 – 100%
  • Bias:
    • Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane: ±(0.15 Vol% + 15% rel.)
    • CO2: ±(0.5 Vol% + 12% rel.)
    • N2O: ± (2 Vol% + 8% rel.)
    • O2: ±3 Vol% 

Networking

  • Industry standard 802.11b/g wireless network

Power

  • Source: External AC power or internal battery
  • AC Power: 100 – 240VAC, 50/60Hz, 150VA
  • Battery: Built-in and rechargeable lithium ion
  • Operating TIme: 3+ hours

Environmental Specifications

  • Temperature:
    • Operating: 5° – 40° C
    • Storage: -20° – 65° C
  • Humidity range:
    • Operating: ≤80 %
    • Storage: ≤80 %
Other Standard Features
  • OxyCRG, drug dose calculation, cascading ECG, On screen NIPB trends (up to 250 readings), user set defaults, Arrhythmia detection, ST segment

Components

Order through your DRE Rep or Online at ORSupply.com

Compatible Supplies

Part Name and DescriptionDRE Part #
Blood Pressure Cuffs
Blood Pressure Cuff HoseINF-20020
Disposable Neonatal Blood Pressure Cuffs - Single Lumen, Male Luer Slip Connectormultiple
DRE Cloth 2-Piece Blood Pressure Cuffs w/Integrated Bladder - Single Lumen, Female Luer Connectormultiple
CO2 / Agent Accessories
CO2 Adult Airway Adapter Kit with Dehumidifier (Pack of 10)INF-5004AAK4
CO2 Sampling Line (Pack of 10)INF-5001SL
External CO2 ModuleINF-5CO2MR
Mainstream Disposable Adult Airway Adapter (Box of 10)INF-5006SPAM
Mainstream Disposable Neonatal Airway Adapter (Box of 10)INF-5006SNAA
Mainstream Reusable Adult Airway AdapterINF-5006RPAA
Mainstream Reusable Neonatal Airway AdapterINF-5006RNAA
Moisture Trap for Anesthetic Agent (5 each)INF-5007MTD
Sample Line for Anesthetic Agent INF-5006SC
Sample Line with Cannula for Anesthetic Agent (Pack of 5)INF-5007SCA
Straight T Adapter INF-5005TA
ECG Cables
3-Lead ECG Cable and LeadsINF-1003L6P0
5-Lead ECG Cable and LeadsINF-1005L6P0
ECG Electrodes
Adult Snap Electrodes Disposable (1,200/Box)INF-100EA
Disposable Pediatric Snap Electrodes (1,500/Box)INF-100EP
IBP
Disposable IV Transducer (Pack of 5)INF-6119
IBP CableINF-6001IPC
Patient Monitor Batteries
Battery for DRE Waveline EZINF-9200
Battery for DRE Waveline PRO & Waveline TouchINF-9100
Power Cord
110V Power CordINF-9001
220V Power CordINF-9002
Printer & Printer Paper
Printer for Waveline MonitorsINF-700P03
Printer Paper for Waveline Pro, EZ, Touch and Plus (5 Rolls)INF-700PP0.5
Rolling Stands & Wall Mounts
Base Plate for Waveline EZINF-8004BP
Base Plate for Waveline PROINF-8003BP
Base Plate for Waveline TouchINF-8002BP
Rolling Stand with BasketINF-800RS
Wall MountINF-800WM
SpO2 Accessories
Digital Adult Oximetry Sensor With Direct ConnectINF-325DFS
Digital Adult Oximety Sensor for Extension CableINF-325DFSEXT
Digital pediatric Oximetry Clip for Direct ConnectINF-345DFSPC
Digital Pediatric Oximetry Clip for Extension CableINF-340DFSPC
Digital Y sensor for Extension CableINF-325DYS
Disposable Digital Adult Oximetry Sensor for Extension CableINF-330DDFSA
Disposable Digital Neonatal Oximety Sensor for Extension CableINF-3300DDFSN
Disposable Digital Pediatric Oximety Sensor for Extension CableINF-3300DDFSP
SpO2 Extension Cables
Digital Oximetry Extension CableINF-325DEC
Temperature Probes
Oral / Rectal Temperature ProbeINF-400T0R
Skin Surface Temperature ProbeINF-400TS
TOP^

Helpful Resources



© DRE INC 2014 all rights reserved.