DRE Echo Portable Vital Signs Monitor

Condition:
  • Factory New
download sales sheetSales Sheet
More Resources
Manuals, Docs, Links
DRE Echo Portable Vital Signs Monitor

Product Description

Ultra-lightweight and portable with a 10 hr battery.

Pre-op/post-op vital signs monitor

 

The accurate, cost-effective DRE Echo vital signs monitor is available in configurations with your choice of SpO2, NIBP and Temperature. The portable monitor has multi-parameter functionality suited for out-patient care and doctor’s offices.

FEATURES

  • NOW with Covidien Quick Temp Technology
  • 5.7 inch high resolution display for easy reading
  • Flexible configurations
  • Built-in rechargeable Lithium-ion battery for 10 hours of continuous working
  • Optional thermometer for obtaining temperature in approximately 15 seconds
  • Real-time parameters measurement display with trend table for easy reviewing
  • Bi-directional communications with central station by wired or wireless network
  • Suitable for adult, pediatric and neonatal patient
  • Nellcor OximaxTM
  • PR measurement (from SpO2/ NIBP)
  • Optional recorder

SPECIFICATIONS

  • Size: 200.8mm (L) x 241mm (H) x 189 mm (D)
  • Weight: 3 kg
  • Display: 5.7 inches,LCD
  • Color TFT resolution: 640X480
  • Power Supply: 100-240 VAC, 50/60HZ
  • Pmax=70VA FUSE T 1.6AL
  • Battery Type: Lithium-ion
  • Voltage: 14.8 V DC Capacitance: 4,400 mAh
  • Working period: Color TFT 480min
  • Rechargeable period: < 360min
  • Recorder: (Optional)
  • Record Width: 48 mm

NIBP

  • Method: Oscillometric
  • Mode: Manual, Auto, Continuous
  • Measuring Interval in AUTO Mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 Min
  • Continuous: 5min, interval is 5s
  • Measuring Type: Systolic Pressure, Diastolic Pressure, Mean Pressure
    Measuring Range
  • Adult Mode
    • SYS: 40~270mmHg
    • DIA: 10~215mmHg
    • MAP: 20~235mmHg
  • Pediatric Mode
    • SYS: 40~200mmHg
    • DIA: 10~150mmHg
    • MAP: 20~165mmHg
  • Neonatal Mode
    • SYS: 40~135mmHg
    • DIA: 10~100mmHg
    • MAP: 20~110mmHg
  • Cuff Pressure measuring Range: 0~290mmHg
  • Pressure Resolution: 1mmHg
  • Maximun mean error: 5mmHg
  • Maximum Standard deviation: 8mmHg
  • Entire Measuring Period 30~45s typical (depend on HR/motion disturbance)
  • Dual Overpressure protection
    • Adult: 297 3mmHg
    • Pediatric: 240 3mmHg
    • Neonatal: 145 3mmHg
  • PR
    • Measuring Range: 40~240bpm
    • Resolution: 1bpm
    • Accuracy: 3bpm or 3% of the maximum
    • IEC 60601-2-30

SpO2

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy
  • Adult (including Pediatric)
    • 2% 70%~100% SpO2
    • Undefined 0~70% SpO2
  • Neonate
    • 3% 70%~100% SpO2
    • Undefined 0~70% SpO2
  • Pulse Rate 
    • Measuring and Alarm Range: 30 ~ 300bpm
    • Resolution: 1bpm
    • Accuracy: 3bpm 
    • Data update period: 2s
    • ISO 9919
TOP^

Helpful Resources



© DRE INC 2014 all rights reserved.