Product Description
Compact Fetal Monitors with High-Sensitivity Transducers
DRE Tempo Series monitors are available with:
- Compact Design
- Easy to move and mount to wall
- Highly Sensitive Transducer
- Uses nine-crystal ultrasound technology
- Automatic Fetal Movement Detection
- Automatically detect fetal movement via ultrasound transducer
- Built-in Thermal Printer
- High resolution, long life printer helps document fetal traces
- Intrapartum Monitor
- Optional DECG and IUP monitoring
- Built-in Network Connecting Interface
- Compatible with wireless and cable LAN obstetrical central station
The DRE Tempo II also features:
- Large display
- Six-inch LCD folding screen simultaneously displays waveforms and digitals
- Powerful memory
- Reload 12 hours of memory for patient data
- Battery
- Built-in rechargeable battery for four hours of continuous work
Features Insight Software that lets you transfer data in real time
- Transfer data to standard PC
- Record events and comments
- Manage patient information
- Print on standard paper
- Store and review patient data
TECHNICAL SPECIFICATIONS
Physical Characteristics
- Dimensions: 330 mm x 270 mm x 100 mm
- Weight: Approx. 3.5 kg
Safety
- Complies with: IEC 60601-1, IEC 60601-1-2
- Anti-electric Shock Type: Class I equipment without internal power supply
- Anti-electric Shock Degree:
– FHR1, FHR2, TOCO, MARK, FS: B
– IUP: BF
– DECG: CF - Working System: Continuous running equipment
Power Supply
- Working Voltage: 100V-240V AC
- Line Frequency: 50/60 Hz
- Pmax: 60VA
- Fuse: TI, 6AL
Environment
- Temperature: 5° C - 40° C
- Relative Humidity: ≤80%
- Atmospheric Pressure: 86KPa - 106KPa
Display
- LED display (Tempo)
- LCD display (Tempo II)
Printing
- Record Paper: Z-fold, thermal paper
- Printing Width: 112 mm
- Effective Printing Width: 104 mm
- Paper Printing Speed: 1 cm/min, 2 cm/min and 3 cm/min
- FHR/DECG Printout Width: 7 cm (USA standard); 8 cm (international standard)
- FHR/DECG Sealing: 30 BPM/cm (USA standard); 20 BPM/cm (international standard)
- TOCO / IUP Printout Width: 3.4 cm (USA standard); 2.4 cm (international standard)
- TOCO / IUP Scaling: 25% / 0.85 cm (USA standard); 25%/0.6 cm (international standard)
- Data Accuracy: ±5% (X axis), ±1% (Y axis)
- Record Message: Date, time, TOCO type, paper speed, FHR type, bed No., etc.
Signal Interface
Ultrasound
- Technique: Pulsed Doppler and auto-correlation
- FHR Range: 50bpm - 210 bpm
- Resolution: 1 bpm
- Accuracy: ±2 bpm
DECG
- Technique: Peak-peak detection technique
- FHR Range: 50 bpm - 210 bpm (international standard), 30 bpm - 240 bpm (USA standard)
- Resolution: 1 bpm
- Accuracy: ±1 bpm
- Input Impedance: >10M (differential, dc to 50/60 Hz)
- Input Impedance: >20 M (common mode)
- CMRR: >110Db
Contraction
- Internal IUP
– Pressure Range (IUP): 0 mmHg - 100 mmHg
– Sensitivity: 5uV/V/mmHg
– Non-linear Error: ±1 mmHg
– Resolution: 1% - External TOCO
– TOCO Range: 0% - 100%, 135 g strength corresponding to 100%
–Sensitivity: 3.7uV/V/mmHg
– Non-linear Error: ≤ ±10%– Resolution: 1%
– Zero Mode: Automatic / Manual
AFM
- Technique: Pulsed Doppler ultrasound
- Range: 0% - 100%
- Resolution: 1%
- Gain Control: Manual / Automatic (Tempo II only)
Mark
- Manual fetal movement mark
Battery
(Rechargeable Lithium-ion Battery – Tempo II only)
- Nominal Capacity: 6000 mAh
- Charge Mode: Constant current/constant voltage
- Nominal Voltage: 14.8V
Model and Feature Comparison Chart
Model | Twin FHR | DECG & IUP | Lithium-ion Battery | Fetal Track Data Storage | Insight Software | Fetal Simulator |
Tempo Basic | No | No | No | No | Yes | Optional |
Tempo Dual | Yes | No | No | No | Yes | Optional |
Tempo Pro | No | Yes | No | No | Yes | Optional |
Tempo II | Optional | Optional | Optional | Yes | Yes | Optional |