DRE Medical Equipment
englishespañol
phone: 1-800-462-8195DRE Facebook PageDRE LinkedIn PageDRE Twitter Profile
This item has been identified as hard to find, discontinued, or unavailable at this time. Although we will be happy to work with you in locating this item, please consider the alternatives listed below.

Refurbished - Criticare Scholar EL Multi-Parameter Monitor

Condition:
  • Retired
Market Availability:
Limited
Refurbished - Criticare Scholar EL Multi-Parameter Monitor

Product Description

Features:

  • Up to ten vital parameters in one system with central station capability
  • Battery back up
  • Interactive, user-friendly data card technology
  • ESI suppression, pacer rejection and defibrillator protection

Specifications:

ECG

  • Number of Leads:  3 or 5 lead wire cables
  • Lead Selection:  I, II, III, a VR, aVL, aVF, V (5 wire cable)
  • Gain Selection:  ½mV, 1mV, 2mV, 4mV, 8mV full scale (all ± 2%)
  • Frequency Response:  Diagnostic:  0.05-100 Hz (-3dB); Monitor: 0.5-40 Hz (-3 dB)
  • Sweep Speed:  6.25, 12.5, 25, 50 mm/sec
Heart Rate Display Alarms
  • User Selectable Choices:  Primary:  ECG; Choices: ECG, Pleth, ART, PA, PW
  • Range:  20-300 BPM
  • Update Time:  Every beat
  • Accuracy:  ±  BPM
  • Alarm Limit Range:  80-300 BMP (high); 20-150 BPM (low)
Non Invasive Blood Pressure
  • Technique:  Oscillometric during inflation
  • Max Inflation Pressure:   Adult 300 mmHg; Neonate:  150mmHg
  • Measurement Cycle:  <40 second average (0-300 mmHg: adult cuff)
  • Automatic Measurement Cycles:  1, 3, 5, 15, 30, 60 minutes
Invasive Blood Pressure (Optional)
  • Number of Channels:  4
  • User Selectable Labels:  ART, PA, ICP, CVP, PW
  • Isolation:  4kV RMS, 5.5 kV peak from ground related currents
  • Pressure Range:  -10 mmHg to 300 mmHg
  • Zero Offset:  ±150 mmHg
  • Probe Impedance:  300-2500 input ohms
  • Frequency Response:  0-20 Hz
  • Input Impendence:  820K @ 20 Hz; >100M @ DC
  • Transducer Sensitivity:  5µV/V/mmHg
  • Zero:  Auto push button
  • Drift:  ±1 mmHg
  • Accuracy:  ±1 mmHg
  • Scale Range:  -10 to 10, 0 to 20, 0 to 40, 0 to 60, 0 to 100, 0 to 150, 0 to 200, 0 to 300
  • Display:  Systolic, diastolic, mean pressure
Impendance Respiration:
  • Rate:  0-150 breaths/minute
  • Resolution:  1 breath/minute
  • Accuracy:  > of ±1% or ±1 breath/minute
Alarms
  • Alarm Indication:  Audible, visual
  • Alarm Silence:  Yes (2 minutes, or permanent)
Temperature (Optional)
  • Number of Channels:  2
  • Range:  20-45° C (68-113° F); ±0.5° C (20-34° C); ±0.2°C (34-41°C); ±0.5°C (41-45°C)
  • Display Resolution:  0.1°C or 0.1°F
Oxygen Saturation
  • Averaging Time:  Selectable 3-21 seconds
  • Search Time:  Selectable, 1-40 seconds
  • Waveform:  User selectable
  • Gain:  User selectable
  • Audio:  Beep with each detected pulse, pitch varies with oxygen saturation
  • Range:  1-99%
  • Resolution:  1%
  • Accuracy:  ±2% (70-99%); ±3% (50-70%)
  • High Saturation Alarm:  Range:  off, 70-99%
  • Low Saturation Alarm:  Range:  off, 1-99%
Physical Properties
  • Size:  16.5 cm (6.5") high x 34.3 cm (13.5") wide x 30.5 cm (12") deep
  • Weight:  5.5 kg (12 lbs) no battery 

 

Suggested Alternatives



TOP^

Recently Viewed Products




RSS