Datex Ohmeda 3800 Pulse Oximeter

Product Description

The 3800 Pulse Oximeter has an easy-to-use interface and intuitive feature set, as well as advanced TruTrak® + technology, a proprietary clinical motion algorithm.

Features:

  • TruTrak+ technology -- a proprietary clinical motion algorithm which identifies, quantifies and corrects clinical patient motion
  • Always-visible Relative Perfusion Index™  (PIr) -- a quick numeric value indicating pulse strength
  • Plethysmographic waveform reinforces clinical decisions
  • Backlit, always-on screen illuminate large numbers for fast recognition of readings
  • Dedicated function keys and an always visible, simple menu system with no hidden functions
  • Continuously displayed alarm limits for decisions at-a-glance
  • Exceeds international durability standards through rigorous stress testing during design and manufacturing processes
  • Full compatibility with all patient types and clinical situations using OxyTip®+ sensors and cables

Physical Specifications:

  • Height: 3.7" (9.4 cm)
  • Width: 9.5" (24.4 cm)
  • Depth: 8.9" (22.5 cm)
  • Weight: 6.1 lbs (2.8 kg) 

Accuracy Specifications: 

SpO2 -

  • Calibration:  Functional
  • Range: 0 to 100%
  • Accuracy (1 standard deviation): 70 to 100% (±2 digits); 70 to 100% (±3 digits during conditions of clinical patient motion with TruTrak+ enabled); Below 70% (unspecified)
  • Resolution:  1%
Pulse Rate -
  • Range: 30 to 255 beats per minute (bpm)
  • Accuracy (assuming a constant pulse rate):  ±2% or ±2 bpm (whichever is greater)
  • Accuracy (during conditions of clinical patient motion):  Unspecified
  • Resolution:  1 bpm
Relative Perfusion Index (PIr) pulsatile value -
  • Range: 0.00 to 9.99
  • Averaging interval: 12 seconds
  • Resolution: 0.01

Operational Specifications:

Alarm Limits:

  • Low SpO2 = OFF or 50 to 100& (preset 85%)
  • High SpO2 = 50 to 100% or OFF (preset OFF)
  • Low pulse = OFF or 30 to 235 bpm (preset: adult = 40 bpm, neonate = 100 bpm)
  • High pulse = 30 to 235 bpm or OFF (preset: adult = 130 bpm, neonate = 200 bpm)

Alarm Silence:

  • 2 minute silence (automatic, 2 min. on start up), all mute capability

Signal Validation:

  • Relative Perfusion Index pulsatile value PerfTrak® waveform display
Memory:
  • 12 hour data storage for SpO2, pulse rate and alarm conditions (1 data point every 6 seconds)
SpO2 Calculation:
  • 30 values per second/60 Hz
  • 25 values per second/50 Hz
Display: 
  • Digital - LED
  • Waveform - Backlit LCD
SpO2 Averaging Modes: 
  • Selectable 3, 6 or 12 seconds (short, medium, long) preset = 12 seconds (long)
Diagnostics:
  • Automatic self test on start up, continuous memory tests during operation
Outputs:
  • Serial (SpO2, pulse rate, alarms, error messages and trend data)

Electrical Specifications:

  • Battery: 8 volt, 3.2 ampere-hours sealed lead-acid.  Continuous charge while operating on AC
  • Charge Time: 100% capacity ≈  8 hours; 80% capacity ≈ 4 hours
  • Operation Time: ≈  5.5 hours on fully charged battery
  • Low Battery Indicator:  "Low Battery" displayed when < 5 minutes remaining
  • Overload Protection: 2 ampere 250V fuses
  • Power Consumption: 15 watts typical
  • Input Voltage: 100 to 240 V, 50/60 Hz

 