GE AMX-III Portable X-Ray Machine

Condition:
  • Refurbished
download sales sheetSales Sheet
More Resources
Manuals, Docs, Links
GE AMX-III Portable X-Ray Machine

Product Description

 

FEATURES

  • MX-75 275k HU X-ray tube with a .75mm focal spot
  • LED display
  • 24 kVp stations
  • 28 mAs stations
  • 100 mA constant
  • kVp 50 –125
  • mAs 0.64 – 320

 

Warranty
  • Eighteen-month warranty on all parts.
  • One-year prorated warranty on the X-ray tube. For warranty purposes, X-ray tubes are valued at $1,500.
  • Two-year manufacturer’s warranty for the lead calcium batteries (the first year they are fully covered and the second year is prorated).

 

TECHNICAL SPECIFICATIONS

Power requirements: Obtained from rechargeable 120V battery

Power required to recharge battery: 110 to 125 VAC, 50/60 Hz, 6.0 amps

Battery capacity: Approximately 10,000 mAs at 100 kVp, when fully charged

Motor drive ratings: The drive assist unit can be driven at speeds up to 180 feet per minute or 54.9 meters per minute

X-ray generator ratings and duty cycle: All radiographic exposures with this unit are at 100 milliamperes

kVp (maximum)

mAs (maximum)

110 to 125

200

95 to 105

250

50 to 90

320

All rates and duty cycles are subject to limitations of the X-ray tube rating and apply at altitudes up to 8,000 feet (2,438 kilometers), average relative humidity not exceeding 80% and ambient temperature between 60º F (15.6º C) and 100º F (37.8º C)

Typical accuracies: ±6% of kVp and ±10% of mAs

 

Selection and Range

Accuracy

0.64 mAs to 1.25 mAs

±30%

1.6 mAs to 10 mAs

±20%

12.5 mAs to 320 mAs

±12%

50 kVp to 74kVp

±(9% + 1kV)

76 kVp to 125 kVp

± (12% + 2 kV)

kVp accuracies subject to additional ±(5% + 2kV) and mAs to ±3% accuracy of instrumentation used for calibration and measurement.

 

Conditions to meet previously mentioned accuracies

  • Handswitch must have been released for 25 seconds after previous exposure.
  • 15-minute interval after change completion with keyswitch in ON or CHARGE.
  • Main power circuit breaker ON must be allowed before making an exposure

 

Collimator Specifications

  • Minimum inherent filtration is 1.5 mm aluminum equivalent to 150 kVp. Additional filtration may be obtained by inserting 1 mm and/or 2 mm aluminum filters.
  • Minimum source-to-skin distance is limited to more than 30 cm by the tracks on the bottom of the collimator for mounting the accessory extension cylinder.
  • Full 17” x 17” (.43 m x .43 m) radiographic coverage at 40” (1.02 m) source to image distance is provided for tubes with a 15-degree target angle.
  • Collimator can be rotated and locked positively at 0º, ±15º, ±30º, ±45º, and ±90º from the front position.

 