DRE Waveline Touch Patient Monitor with Touch-Screen

Condition:
  • Factory New
download sales sheetSales Sheet
More Resources
Manuals, Docs, Links
Waveline Touch Patient Monitor
DRE Waveline Touch Patient Monitor with Touch-ScreenDRE Waveline Touch Patient Monitor with Touch-ScreenDRE Waveline Touch Patient Monitor with Touch-Screen

Product Description

<

User-friendly touch-screen patient monitor measures ECG, SpO2 , NIBP, heart rate, temperature and respiration.  Offers optional dual IBP, and EtCo2.

DRE Waveline Touch Touch-screen Patient Monitor

FEATURES:

  • New - Optional Plug-In Anesthesia Gas Module expands measurement capabilities -- Anesthesia Gas Module
  • EtCO2 Option allows compliance with ASA
  • Available with optional dual invasive blood pressures, EtCO2, a battery and a built-in recorder.
  • 12.1” color TFT display with a touch-screen interface
  • Multi-lead ECG monitoring
  • Built-in battery (optional)
  • NIBP list display
  • Built-in thermal recorder
  • Networkable with a central monitoring system via a wireless or wired network
  • 72 hours trend data analysis
  • Compact design convenient for mobile monitoring
  • Multi-lingual settings

Physical Dimensions & Weight

  • Main Unit - Dim. 555mm H x 335mm W x 235mm D
  • Weight - 5kg

Application

  • Neonatal, pediatric and adult patients

Operation Environment

  • Power Source - External AC power or internal battery
  • AC Power - 100-240VAC, 50/60Hz, <150VA
  • Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour); Operating time after the first alarm of low battery (10 min.)

Temperature

  • Working - 5°-40° C
  • Storage - -20°-65° C

Performance Specifications

  • Display - 12.1” color TFT, Touch Screen
  • Resolution - 800 x 600 pixels
  • Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
  • Indicator - Alarm indicator; Power indicator QRS beep and alarm sound
  • Trend Time - 72 hours
  • Recorder - Built-in, thermal array, 2 channels
  • Record - Width 48mm
  • Recorder - Paper 50mm
  • Record - Speed 25mm/s, 50mm/s

ECG

  • Input - 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice - I, II, III, aVR, aVF, aVL, V
  • Gain Choice - x0.5, x1.0, x2.0
  • Frequency Characteristic - 0.05-40 Hz
  • ECG Waveforms - 7 channels
  • Penetration Voltage - 4000VAC 50/60Hz
  • Sweep Speed - 12.5, 25 and 50 mm/s
  • HR Display Range - 30-300bpm
  • Accuracy - ±1% or ±1bpm, whichever is greater
  • Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm

RESP

  • Measure Method - RA-LL impedance
  • Range - 0-120 rpm
  • Accuracy - + 3 rpm
  • Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm
  • Sweep Speed - 12.5 and 25 mm/s

NIBP (Suntech)

  • Measuring Technology - Automatic oscillating measurement
  • Cuff Inflating - <30s-0-300 mmHg, standard adult cuff
  • Measuring Period - AVE<40s
  • Mode - Manual, Auto, STAT
  • Measuring Interval in AUTO Mode - 2 min-4 hrs
  • Pulse Rate Range - 30-250 (bpm)
  • Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
  • Resolution - 1mmHg
  • Accuracy - Pressure, Maximum Mean error ±5mmHg, Max. Standard deviation 8mmHg
  • Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
  • Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg

TEMP

  • Range - 25°-50° C
  • Accuracy - + 0.2 °C 25.0°-34.9° C; + 0.1° C 35.0°-39.9° C; + 0.2° C 40.0°-44.9° C; 0.3° C 45.0°-50.0° C
  • Display Resolution - 0.1° C
  • Alarm Upper-lower Limit Setting - Upper limit 0-50° C, Lower limit 0-50° C
  • Channel - 2 channels
  • Alarm Limit Setting - 10-50° C

SPO2

  • ASpO2 Anti-motion SpO2
  • SpO2% Range 0-100%
  • SpO2 Accuracy + 2% 70-100%, nonmotion; + 3% 70-100%, motion
  • Pulse Rate Range 30-250 bpm
  • Pulse Rate Accuracy ±2 bpm (non-motion); ±3 bpm (motion)
  • Alarm Upper-lower Limit Setting: Upper limit 70-100%, Lower limit 70-100%
  • SpO2 Probe - Red Light LED Wavelength 660nm±5nm, Infrared Light LED
  • Wavelength - 940nm±10nm

IBP (Option)

  • Measurement Range - -10-300mmHg
  • Channel - 2 channels
  • Pressure Transducer Sensitivity, 5μV/V/mmHg
  • Impedance Range - 300-3000Ω
  • Transducer Sites - ART, PA, CVP, RAP, LAP, ICP
  • Resolution - 1mmHg
  • Accuracy - ±1mmHg or ±2%, whichever is greater
  • Alarm range - -10-300mmHg

EtCO2 (Option)

  • EtCO2 Option allows compliance with ASA
    Standards for Basic Anesthetic Monitoring (Effective July 1, 2011) - PDF Download
  • Mode of Sampling - Sidestream
  • Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
  • CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
  • CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated)
  • CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg)
  • CO2 Accuracy - 0-40 mmHg ± 2 mmHg; 41-70 mmHg ± 5% of reading; 71-100 mmHg ± 8% of reading; 101-150 mmHg ± 10% of reading; Above 80 breath per minute ± 12% of reading
  • Sampling Rate - 100Hz
  • Respiration Rate - 2-150 bpm
  • Respiration Rate Accuracy - ±1 breath
  • Response Time - <3 seconds - includes transport time and rise time
  • Inspired CO2 Measurement Range - 3-50 mmHg
Order through your DRE Rep or Online at ORSupply.com

Compatible Supplies

Part Name and DescriptionDRE Part #
Blood Pressure Cuffs
Blood Pressure Cuff HoseINF-20020
DRE Cloth 2-Piece Blood Pressure Cuffs w/Integrated Bladder - Single Lumen, Female Luer Connectormultiple
Trimline Disposable Neonatal Blood Pressure Cuffs - Single Lumen, Male Luer Slip Connectormultiple
CO2 / Agent Accessories
CO2 Adult Airway Adapter Kit with Dehumidifier (Pack of 10)INF-5004AAK4
CO2 Sampling Line (Pack of 10)INF-5001SL
External CO2 ModuleINF-5CO2MR
Mainstream Disposable Adult Airway Adapter (Box of 10)INF-5006SPAM
Mainstream Disposable Neonatal Airway Adapter (Box of 10)INF-5006SNAA
Mainstream Reusable Adult Airway AdapterINF-5006RPAA
Mainstream Reusable Neonatal Airway AdapterINF-5006RNAA
Moisture Trap for Anesthetic Agent (5 each)INF-5007MTD
Sample Line for Anesthetic Agent INF-5006SC
Sample Line with Cannula for Anesthetic Agent (Pack of 5)INF-5007SCA
Straight T Adapter INF-5005TA
ECG Cables
3-Lead ECG Cable and LeadsINF-1003L6P0
5-Lead ECG Cable and LeadsINF-1005L6P0
ECG Electrodes
Adult Snap Electrodes Disposable (1,200/Box)INF-100EA
Disposable Pediatric Snap Electrodes (1,500/Box)INF-100EP
IBP
Disposable IV Transducer (Pack of 5)INF-6119
IBP CableINF-6001IPC
Patient Monitor Batteries
Battery for DRE Waveline EZINF-9200
Battery for DRE Waveline PRO & Waveline TouchINF-9100
Power Cord
110V Power CordINF-9001
220V Power CordINF-9002
Printer & Printer Paper
Printer for Waveline MonitorsINF-700P03
Printer Paper for Waveline Pro, EZ, Touch and Plus (5 Rolls)INF-700PP0.5
Rolling Stands & Wall Mounts
Base Plate for Waveline EZINF-8004BP
Base Plate for Waveline PROINF-8003BP
Base Plate for Waveline TouchINF-8002BP
Rolling Stand with BasketINF-800RS
Wall MountINF-800WM
SpO2 Accessories
Digital Adult Oximetry Sensor With Direct ConnectINF-325DFS
Digital Adult Oximety Sensor for Extension CableINF-325DFSEXT
Digital pediatric Oximetry Clip for Direct ConnectINF-345DFSPC
Digital Pediatric Oximetry Clip for Extension CableINF-340DFSPC
Digital Y sensor for Extension CableINF-325DYS
Disposable Digital Adult Oximetry Sensor for Extension CableINF-330DDFSA
Disposable Digital Neonatal Oximety Sensor for Extension CableINF-3300DDFSN
Disposable Digital Pediatric Oximety Sensor for Extension CableINF-3300DDFSP
SpO2 Extension Cables
Digital Oximetry Extension CableINF-325DEC
Temperature Probes
Oral / Rectal Temperature ProbeINF-400T0R
Skin Surface Temperature ProbeINF-400TS
TOP^

Helpful Resources



TOP^

Recently Viewed Products




© DRE INC 2012 all rights reserved.