DRE offers the Respironics Novametrix Tidal Wave model 715Sp portable handheld pulse oximeter and CO2 monitor with SpO2. The Tidal Waves are the only handheld, mainstream capnographs available today, and provide immediate feedback on the patient's airway condition and ventilatory status. Based on the same technology as Respironics Novametrix bedside capnographs.
THREE OPTIONAL CONFIGURATIONS:
FEATURES:
CAPNOGRAPH
Principle of Operation
Solid state mainstream sensor. Single beam, non-dispersive infrared (NDIR) absorption, ratiometric measurement.
Initialization Time
Capnogram within 15 seconds, full specifications within 60 seconds.
Calibration
No calibration required.
CAPNOSTAT® Mainstream CO2 Sensor
Size: 3.30 × 4.24 × 2.16 cm (1.30 × 1.67 × 0.85 in.).
Weight: 18 grams (0.64 oz.), cable excluded
Shock Resistance: Withstands repeated six foot drops to a hard surface.
CO2 (Carbon Dioxide)
Range: 0 - 150 mmHg
Accuracy:
±2 mmHg (for 0 - 40 mmHg),
±5% of reading (for 41 - 70 mmHg),
±8% of reading (for 71 - 150 mmHg)
Resolution: 1 mmHg
Response Time: 60 ms
Units: mmHg, kPa, or %
Compensations: N2O & O2 (selectable), Pb (automatic)
Capnogram: Selectable sweep speed
Respiratory Rate
Accuracy: ±1 br/min
Range: 0-150 br/min
Resolution: 1 br/min
Sampling Flow Rate (Model 715 only)
180 ml/min (for non-intubated patients)
Response time is less than 200 ms at 180 ml/min flow
PULSE OXIMETER
Principle of Operation
Red/Infrared absorption.
SpO2 (Oxygen Saturation)
Range: 0-100%
Accuracy: ±2% SpO2 (for 80-100% SpO2)
(1 SD, or 68% of readings within claim) Unspecified for 0-79% SpO2
Resolution: 1%
Averaging: Menu selectable 2 or 8 seconds
Pulse Rate
Range: 30-250 bpm
Accuracy: ±1% of full scale
Resolution: 1 bpm
Averaging: 8 seconds
Sensors
Reusable Y-Sensor (can be sterilized and used with all patient populations);
reusable adult finger sensor
GENERAL
Alerts
Limits:Adjustable limits for ETCO2, SpO2, Respiratory Rate and Pulse Rate. No Respiration Detected adjustable timeout.
Audio: Adjustable volume, two minute silence or off (LED indicators)
Visual: On-screen and LED
Display
Type: Dot matrix, backlit (LCD)
Size: 2.2 × 1.1 inches
Trending Capabilities
Memory: 24 hr., battery backed
Format: 30 minute on-screen or printed in trend or tabular mode.
Download data to personal computer for use with NovaCARD software
Communication Output
RS232 to Seiko DPU-414 printer, NovaCARD software or computer
Physical
Size (height, width, depth): 20 × 9.5 × 4.8 cm (8 × 3.75 × 1.875 in.).
Weight: 793 grams (28 oz.).
Electrical
External Supply (optional)
Input: 120 VAC 60 Hz, or 220 VAC 50 Hz
Battery: Nickel-Metal-Hydride (NiMH): 4.5 hour life
Battery: Standard AA lithium: 5.5 hour life
Environmental
Operating temperature: 0 to +40 °C (32-104 °F)
Operating humidity: 0 to 90% RH non-condensing.