Product Description
Compact design. Unmatched clinical performance.
- Masimo SET® pulse oximetry: proven accurate during motion and low perfusion in over 100 independent clinical studies.
- The accuracy of Masimo SET oximetry has been linked to improved care and reduced medical errors.
- Compact, lightweight design with extended battery life for transport applications.
- Large LED color display is easy to read at a distance.
- Ideal for acute and alternate care use; includes configurable Sleep and Home modes.
Features
- Trauma Mode is used to quickly set the unit into the most sensitive mode and fastest averaging time for patients in resuscitation/trauma situations
- Sleep Mode easily configures system to perform bedside studies
- Home Mode allows for safe and accurate monitoring and trending at home
- RadNetTM and RadLink® interface capability for multipatient remote monitoring
- Perfusion Index (PI) indicates arterial pulse signal strength and may be used as a diagnostic tool during low perfusion
- Low Signal IQ® (SIQ) indicator highlights conditions of low signal quality
- FastSatTM tracks rapid changes in arterial O2 with high fidelity unlike any other pulse oximeter
- APODTM (Adaptive Probe Off Detection) offers the best probe off detection of Masimo's three sensitivity modes - APOD, Normal and MAX sensitivity
- Adjustable averaging 2 to 16 seconds
- Nurse call interface
- Over 8 hours of internal battery life when fully charged
- 72 hours of trending memory
- Available in horizontal and vertical configurations
- Compatible with Philips Vuelink® device interface module
Performance
Measurement Range:
- SpO2: 1 - 100%
Pulse Rate: 25 - 240 beats per minute (bpm)
Perfusion Index: 0.02% - 20%
Saturation Accuracy:
- Saturation: 70% to 100%
- No Motion:
- Adults, Pediatrics: ±2 digits
- Neonate: ±3 digits
Motion
- Adults, Pediatrics: ±3 digits
- Neonate: ±3 digits
Low Perfusion
- Adults, Pediatrics: ±2 digits
- Neonate: ±3 digits
Pulse Rate Accuracy:
- Pulse rate: 25 - 240 bpm
- No Motion:
- Adults, Pediatrics, Neonate: ±3 digits - Motion:
- Adults, Pediatrics, Neonate: ±5 digits - Low Perfusion:
- Adults, Pediatrics, Neonate: ±3 digits - Resolution:
- Saturation (%SpO2): 1%
- Pulse Rate (bpm): 1 bpm
Electrical
- AC Power requirements: 100-240 VAC, 47-83 Hz
- Power consumption: 15 VA
Batteries - Handheld
- Type: Sealed lead acid
- Capacity: 8 hours
- Charging time: 8 hours
Environmental
- Operating Temperature: 41°F to 104°F (5°C to 40°C)
- Storage Temperature: -40°F to 158°F (-40°C to +70°C)
- Operating Humidity / Storage: 5% to 95%, non-condensing
- Operating Altitude: 500 mbar to 1060 mbar pressure -1000 ft to 18,000 ft (-304 m to 5,486 m)
Physical Characteristics
- Dimensions: 8.2” x 6.0” x 3.0” (20.8 cm x 15.2 cm x 7.6 cm)
- Weight: 2.1 lbs = .908 kg = 32 oz
Modes
- Averaging mode: 2, 4, 8,10,12,14 or 16 seconds
- Sensitivity: APOD, Normal and Max
Alarms
Audible and visual alarms for high and low saturation (1% to 100%), pulse rate (25 - 240 bpm), sensor condition, system failure and low battery
Display/Indicators
- Data display: %SpO2, pulse rate, alarm status, alarm silenced status, AC power, Signal IQ / pleth bar, perfusion index bar, battery status, no sensor, sensor off
- APOD, Norm, Max, FastSat, Trauma: LED
- Type: LED
Output Interface
- Serial RS-232
- Nurse Call
Compliance
- EMC Compliance: EN60601-1-2, Class B
- Equipment Classification: IEC 60601-1/ UL 60601-1
- Type of Protection:
- Class 1 (on AC power)
- Internally powered (on battery power) - Degree of Protection - Patient Cable: Type BF-Applied part
- Mode of Operation: Continuous
| Name | Model | | |
| Rad-8 HomeCare Kits with Sensor | | | |
| Rad-8 HomeCare Kits with Sensor | | | |
TOP^Recently Viewed Products