Baxter's Colleague Volumetric Infusion Pump is designed to meet the fluid delivery needs of today's evolving healthcare environment. The Colleague 3 Pump can be utilized for continuous or intermittent delivery through clinically acceptable routes of administration such as, intravenous (IV), intra-arterial (IA), subcutaneous, epidural, or irrigation of fluid spaces applications.
Fluid delivery applications include:
- Parenteral fluids, drugs and electrolytes; e.g., cardiovascular drugs, antibiotics, anesthetics, analgesics, chemotherapy agents, total parenteral nutrition products, lipids, solutions for irrigation procedures, etc.
- Whole blood and blood products.
The Colleague Volumetric Infusion Pump feature spectrum includes:
- Micro and Macro Rate Range
- Basic Delivery Programming
- Piggybacking Secondary Medications
- Special Programming functions for Dosing
SPECIFICATIONS
- Ac power Requirements: 100-120 VAC, 60Hz
- Leakage Current: Less than 300 u amps earth leakage (tested per UL 2601)
- External Fuses: 1.6 amp Type T (time delay) 250V
- Power Cord: 2.9 m (9 feet) long with integrally molded hospital grade plug
- Battery Supply System: Colleague 3 Pump - 3 hours operating time at 100 mL/hr for all three channels (fully charged new batteries) 12 hours to recharge to 80% of capacity Internal charge system recharges batteries whenever the device is connected to an AC outlet
Range of Programmable Flow Rates Primary Infusion on each pump channel 0.1 to 99.9 mL/hr in 0.1 mL/hr increments 1 to 1200 mL/hr in 1 mL/hr increments Piggyback Infusion on each pump channel 0.1. to 99.9 mL/hr in 0.1 mL/hr increments 1 to 500 mL/hr in 1 mL/hr increments Note: Rate limits can be configured for values less Than those stated above.
- Volume to be Infused: 0.1 - 99.9 mL in 0.1 mL increments 1- 9999 mL mL/hr in 1 mL increments
Note: Volume to be Infused limits can be configured for values less than those stated above
- KVO: 0.1 - 5 mL/hr in 0.1 mL increments (configurable option) or programmed rate whichever is less.
- Priming rate: 500 mL/hr (to be used only when not connected to patient)
- Advance Air Rate to Advanced an Air Bubbles: At the same rate programmed for the current primary or piggyback infusion.
- Air Bubble Setting: Measured accumulations of approximately
- 25 microliters
- 50 microliters
- 100 microliters
- 150 microliters
The Air Bubble Setting is a configurable option.
- Auto Restart: Allows the pump channel to automatically restart if an occlusion is relieved within one minute after detection. This configuration option allows 0 to 9 restarts before manual intervention is required.
- Device Size: Approximately 13.88" H x 7.75" W x 8.00" D (353 x 197 x 203 mm), not including clamp knob or power cord
- Device weight: Approximately 17.5 lbs (7.9 kg)
- Environmental Operating Limits: 59º F - 100º F (15º C - 38º C)
- Environmental Storage and Transport Limits: -20º F - 135º F (-29ºC - 57º C), 10-100% Reliable Humidity including condensation, 500-1060 hPa Barometric Pressure