DRE is now Avante Medical Surgical

Visit our new website by using the "Proceed to new URL" button.

Critikon Pro 100 NIBP Monitor - Refurbished

(800) 462-8195

Description

The Pro 100 monitor enhances productivity with easy to use features and an intuitive menu structure. With a properly-sized BP cuff in place, just press the large gray knob to take a BP reading. It's that easy. All Pro Series Monitors are fully upgradeable so they can grow with your changing needs.

Benefits:

  • Comprehensive - One monitor for the entire range of patient populations - Neonatal, Pediatric and Adult
  • Versatile - Used in ER, Outpatient Surgery, Endoscopy, GI Lab Special Procedures, Recovery/PACU, Telemetry, Med-Surg and Labor & Delivery
  • Easy To Use - Common User Interface with GE monitors throughout the continuum of care, so floating nurse ca assess patients with the touch of a button
  • Six Sigma Quality and Reliability - Built-in quality means accurate readings

Features

  • NIBP
  • SpO2
  • Temperature monitor
  • Recorder
  • Offers reliable automated blood pressure and pulse rate information that has been clinically proven as accurate again and again

Specifications

General

  • Dimensions: 25 × 25 × 18 cm (H × W × D)
  • Weight: 3.5 kg (including battery)
  • NIBP Accuracy: Meets or exceeds ANSI/AAMI standard SP-10
  • Default Target: Adult: 160 ± 15mmHg; Cuff inflation, Neonatal: 110 ± 15 mmHg
  • Target Cuff Inflation: Adult: 100 to 250 mmHg; Neonatal: 100 to 140mmHg
  • Systolic Range: Adult 30 to 245 mmHg, Neonatal: 40 to 140 mmHg
  • Diastolic Range: Adult 10 to 195 mmHg, Neonatal: 20 to 100 mmHg
  • MAP Range: Adult: 15 to 215 mmHg, Neonatal: 30 to 115 mmHg
  • Pulse Rate Accuracy: NIBP ±3.5%; SpO2: ±3 bpm
  • Pulse Rate Range: NIBP: Adult: 30-200 bpm, Neonatal: 30-200 bpm, SpO2: 20 to 250 bpm
  • Temperature Accuracy: Monitor mode: ±1°C, predictive mode: ±0.6°C
  • Temperature Range: Monitor mode: Max: 42.2°C, Min: 26.7°
  • Predictive Mode: Max: 42.2°C; Min: 31.6°C
  • Pulse Oximeter Accuracy: Adult: 70-100% ±4.5 digits, 0-69% unspecified; Neonatal: 70-100% ±4.5 digits, 0-69% unspecified
  • Power Requirements: AC input voltage: 100-240 VAC, 50/60 Hz (nominal); Internal battery: Sealed lead acid 12V 2.3Ah

Accessories & Supplies

Web ID Compatible ECG Cables, Leads, & Electrodes Part #  
12590 3-Lead ECG Trunk Cable
12592 3-Lead ECG Lead Set - Snap Style
12596 3-Lead ECG Lead Set - Grabber Style
12597 3-Lead ECG Direct Connect Cable & Set - Snap Style
12598 3-Lead ECG Direct Connect Cable & Set - Grabber Style
12591 5-Lead ECG Trunk Cable
12599 5-Lead ECG Lead Set - Snap Style
12600 5-Lead ECG Lead Set - Grabber Style
12601 5-Lead ECG Direct Connect Cable & Set - Snap Style
12602 5-Lead ECG Direct Connect Cable & Set - Grabber Style
12603 ECG Electrodes - Snap Style - Per Case of 1000
12604 ECG Electrodes - Grabber Style - Case of 1000
Web ID Compatible Sensors & Probes Part #  
12614 Temperature Sensor - Skin
12615 Temperature Sensor - Oral / Rectal
12605 SPO2 Sensor - Adult Direct Connect - Reusable
12606 SPO2 Sensor - Pediatric Direct Connect - Reusable
12609 SPO2 Extension Cable
12607 SPO2 Sensor - Adult Probe for use with Cable - Reusable
12608 SPO2 Sensor - Pediatric Probe for use with Cable - Reusable
12610 SPO2 Sensor - Adult - Disposable
12611 SPO2 Sensor - Pediatric - Disposable
12612 SPO2 Sensor - Infant - Disposable
12613 SPO2 Sensor - Neonate - Disposable
Web ID Compatible Blood Pressure Cuffs Part #  
12620 Blood Pressure Cuff - Large Adult
12621 Blood Pressure Cuff - Adult
12625 Blood Pressure Cuff - Adult Thigh
12622 Blood Pressure Cuff - Small Adult
12623 Blood Pressure Cuff - Child
12624 Blood Pressure Cuff - Infant
Web ID Compatible Monitor Batteries, Paper, and Stands Part #  
12616 Printer Paper - Box of 10
12617 Compatible Long Life Battery
12618 Monitor Rolling Stand
12619 Monitor Wall Mount Kit