DRE is now Avante Health Solutions

Visit our new website by using the "Proceed to new URL" button.

DRE Trax Vital Signs / ETCO2 Monitor

(800) 462-8195

DRE Trax Vital Signs / ETCO2 Monitor

Web ID: 2379

Condition: Factory New

Part Number: 66311x (x = additional suffix for varying configurations

0 items are in your cart. View cart now.

Need Advice? Ask Our Experts!

(800) 462-8195

Description

The DRE Trax is a versatile, intuitive patient vital signs monitor that can be configured to measure any combination of non-invasive blood pressure, SpO2, rapid temperature, and capnography ( EtCO2 Monitoring ). The Trax simplifies clinician use by incorporating a touchscreen with a simple user interface.

The Trax is ideal for bedside measurement in low-acuity post-anesthetic care, sleep studies, and patient transport, and is applicable in many other care areas. The Trax can be configured as a basic continuous pulse oximeter or a blood pressure pulse oximeter combo. EtCO2 can also be added as a 3rd parameter. The Trax can be used with only EtCO2 as a standalone capnograph for specialized clinical applications.

Weighing less than 3 lbs, the portable Trax is well suited for any patient care area. Wall mounts and mobile mounting solutions are available. A long-life lithium ion battery is standard.

Non-proprietary sample lines allow the Trax to be the industry's lowest cost-per-patient end-tidal CO2 monitor. The capnography system is a cutting-edge, low-flow end-tidal CO2 measuring system. It uses a 50-ml-per-minute sidestream method to deliver the most accurate EtCO2 readings. It can be used on both intubated and non-intubated patients. The sample line connection system uses filter cells to eliminate the potential of cross contamination.

Capnography is outpacing Pulse Oximetry as the new standard of care in outpatient surgery procedures. Click to see the dramatic difference between CO2 and SPO2.

Specifications

  • Optional ETCO2 Monitoring
  • All patient data can be transmitted through Trax's many network optionS
  • 72-hour trending
  • Simplified patient information entry.

Specifications

General

  • Display: 5.0 inch (Diagonal) color TFT
  • Resolution: 800 × 3(RGB) × 480
  • Trace: 2 waveforms
  • Waveforms: PLETH, ETCO2
  • Trend time: From 1 to 72 hours
  • Indicator:
    • Alarm Indicator
    • Power indicator
    • Pulse beep and alarm sound

NIBP

  • Measuring Technology: Automatic oscillating measurement
  • Cuff Inflating: <30s (0 ~ 300 mmH, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto, STAT
  • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
  • Pulse Rate Range: 30 bpm ~ 250 bpm
  • Measuring Range: Adult/Pediatric Mode
  • SYS: 40 ~ 250 (mmHg)
  • DIA: 15 ~ 200 (mmHg)
  • Neonatal Mode
  • SYS: 40 ~ 135 (mmHg)
  • DIA: 15 ~ 100 (mmHg)
  • Resolution: 1mmHg
  • Pressure Accuracy: Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: 8mmHg
  • Overpressure Protection: Adult Mode: 280(mmHg)
  • Neonatal Mode: 150 (mmHg)
  • Alarm Limit: SYS: 50 ~ 240 mmHg
  • DIA: 15 ~ 180 mmHg
  • Standards: Meets performance standards of ANSI/AAMI SP10:2002

SPO2

  • ASpO2: Anti-motion SpO2
  • SpO2% Range: 0 ~ 100%
  • SpO2 Accuracy: ±2% (70 ~ 100%,non-motion)
  • ±3% (70 ~ 100%, motion)
  • Pulse Rate Range: 30-250 bpm
  • Pulse Rate Accuracy: ±2 bpm(non-motion), ±3 bpm (motion)
  • Alarm Upper-lower Limit: Upper limit 70 ~ 100%, Lower limit 70 ~ 100%
  • SpO2 Probe: Red light LED wavelength: 660nm±5nm
  • Infrared light LED wavelength: 940nm±10nm
  • Standards: Meets performance standards of EN ISO 9919:2005

Rapid Temperature (Option)

  • Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
  • Typical Measurement Times
  • Oral (Quick Mode):3-5 seconds (non-fever temps), 8-10 seconds (fever temps):
  • (after insertion into measurement site):
    • Oral (Standard Mode): 6-10 seconds
    • Axillary Mode: 8-12 seconds
    • Rectal Mode: 10-14 seconds
    • Direct Mode (All Sites): 60-120 seconds
  • Approx. 6000 temperature readings
  • Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
  • Pulse Timer: 60 Second count with a "beep" at 15 seconds, 2 "beeps" at 30 seconds, 1 "beep" at 45 seconds, and 2 "beeps" at 60 seconds
  • Patient Accuracy: A Standard Prediction Mode reading and a Direct Mode reading will differ by less than ±0.2°C (±0.4°F) on 98% of tested patients
  • Batteries:
    • Four "AA" Required.
    • Standard IEC package size.
    • Alkaline --1.5 Volt

EtCO2 (Option)

  • Mode of Sampling: Sidestream or Mainstream
  • Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
  • CO2 measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
  • CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
  • CO2 Resolution: 0.1mmHg (0-69mmHg), 0.25mmHg (70-150mmHg)
  • CO2 Accuracy:
    • 0 ~ 40 mmHg ± 2 mmHg
    • 41 ~ 70 mmHg ± 5% of reading
    • 71 ~ 100 mmHg ± 8% of reading
    • 101 ~ 150 mmHg ± 10% of reading
    • Above 80 breath per minute ± 12% of reading
  • Sampling rate: 100Hz
  • Respiration Rate: 2 ~ 150 bpm
  • Respiration Rate accuracy: ±1 breath
  • Response Time: <3 seconds -
  • includes transport time and rise time
  • Inspired CO2 measurement Range: 3 ~ 50 mmHg
  • Standards: Meets performance standards of ISO/FDIS 21647:2004 (E), ASTM F1456-01, IEC/CDV 60601-2-55

Networking

  • Wired Networking:
    • Industry standard 802.11b/g wired network
    • Frequency Range: 2.412 ~ 2.484 GHz
    • Connected bedside number: Up to 16 bedside monitors
  • Wireless Networking:
    • Up to 100m indoors
    • Industry standard 802.11b/g wireless
    • Supports TCP/IP and UDP/IP Protocols

Power

  • Source: External AC power or internal battery
  • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery: Built-in and lithium Ion rechargeable, 12.6V/5Ah
  • Charge Time: 8 hours
  • Operating Time: 3 hours

Environmental

  • Temperature: Operating: 5 ~ 40 °C
  • Storage: -10 ~ 45 °C
  • Humidity Range: Operating: ≤80 %
  • Storage: ≤80 %

FUSE

  • 3.15A/250V

LCD

  • Display Type: TFT color LCD
  • Size (diagonal): 5.0 inch
  • Active Area: 152.4 (W) × 91.44 (H) mm
  • Color arrangement: RGB-stripe
  • Dot pitch: 0.0635(W) × 0.1905(H) mm
  • Display Mode: Normally white, Transmissive
  • Interface: Digital (TTL)
  • Surface Treatment: Anti-Glare

Touchscreen

  • Type: Four-Wire Analog Resistive Touch Panel
  • Input Mode: Stylus Pen or Finger
  • Connector: FPC
  • Insulation resistance: 25Mω
  • Voltage: 7VDC
  • Chattering: 10ms
  • Transparency: 80%
  • Surface hardness: 3H
  • Durability-surface scratching: Write 100,000
  • Active force: 80gf
  • Knock Test: 1,000,000 times

Accessories & Supplies

Web ID CO2 Cannulas Part #  
513 CO2 Sampling Cannula with Split O2 Delivery P03082D