Integrates microprocessor-based controls with a modular design for efficient patient care
The GE Care Plus 4000 is an advanced incubator that provides superior thermoregulation with an integrated microprocessor-based controller. Optional active double-wall construction creates a precise and consistent environment for the neonate.
Features
Microprocessor-based control system for accurate thermoregulation
Self-test functions at power-up and during normal operation
Patient control (Servo) mode and air control (Manual) modes
Continuous positioning from 0° to 12°
Optional active double-wall construction
Specifications
Dimensions
Incubator with Elevating Base
Height: 54 - 62 in (136.2 - 157.5 cm)
Elevating base: 35 - 43 in (88.9 - 109.2 cm) mattress to floor
Depth: 28 in (71.1 cm)
Width: 33 in (83.8 cm)
Weight: 195 lbs (89 kg)
Incubator with Stationary Pedestal
Height: 53 in (135.9 cm)
Depth: 28 in (71.1 cm)
Width: 33 in (83.8 cm)
Weight: 180 lbs (80 kg)
Drawer Packages for Elevating Base or Stationary Pedestal
Overall: 11 x 11.5 x 18.25 in (28 x 29 x 46 cm)
Single deep drawer: 10 x 9 x 16.5 in (25 x 23 x 42 cm)
Dual drawer: 4.5 x 9 x 16.5 in (11 x 23 x 42 cm)
Incubator with Cabinet
Height: 55 in (141 cm)
Depth: 25.5 in (64.6 cm)
Width: 35 in (88.9 cm)
Weight: 185 lbs (84 kg)
Incubator Characteristics
Casters: 5 inch diameter, 2 locking, 2 non-locking
Mattress: 13.7 x 25.6 in (34.8 x 65 cm)
Mattress to Hood: 16 in (41 cm)
Door Height: 11 in (28 cm)
Positions: Continuous from 0° to 12°
Port holes: 6
Tubing ports: 6
Electrical
120 VAC 60 Hz
Models: 115 V ± 10% 5.7 amps
Conforms to IEC 601.1, UL 544 and CSA 22.2 No. 125 requirements
Nominal power consumption: 450 watts at maximum heater output
Line voltage compensation: Input voltage is monitored and the heat output is adjusted to compensate for line voltage variations
Leakage currents: Less than 100 micro amps on 120V units
Leakage at patient probe: Less than 50 micro amps on 120V units
Environment
Operating temperature range: 68° - 86°F (20° - 30°C)
Storage temperature range: 13° - 140°F (-25° - 60°C)
Operating humidity range: 0 to 90%
System Controls
Microprocessor-based control system: Self-test functions are performed at power-up and during normal operation
Patient Control (Servo) Mode: 95° - 98.6°F (35° - 37°C)
Air Control (Manual) Mode: 73.4° - 98.6°F (20° - 37°C)
Up to 102.2°F (39°C) with control panel override switch
Air Velocity: Average < 10 cm/sec with inner wall
Temperature variability: Less than ± 0.2°F (0.1°C)
Resolution: ± 0°F (0.1°C)
Probe or interchangeability: ± 0.2°F (0.1°C)
Average Oxygen Input Concentration Range: 5 L/min 25-45% | 10 L/min 35-65% | 15 L/min 45 to 70%
Humidification: Standard — 10 to 75% dependent on nursery environment and incubator temperature setting | Servo — 40 to 85% regardless of nursery environment and incubator temperature setting