DRE is now Avante Medical Surgical

Visit our new website by using the "Proceed to new URL" button.

Philips SureSigns VM1 Vital Signs Monitor - Refurbished

(800) 462-8195

Philips SureSigns VM1 Vital Signs Monitor - Refurbished

Web ID: 12633

Condition: Refurbished

0 items are in your cart. View cart now.

Need Advice? Ask Our Experts!

(800) 462-8195

Description

The Philips SureSigns VM1 is a multi-parameter vital signs monitor designed for any care environment and suitable for adult, pediatric or neonatal use. For more information, contact a DRE Representative today.

Features

  • Multi-parameter monitor designed for adult, pediatric and neonatal patients.
  • Compact design with sturdy handle for easy portability.
  • Backlit, color-coded display panel for clear readings in any environment.
  • Philips SpO2 technology supports sensors from industry-leading brands in adult, pediatric and neonatal configurations.
  • Display panel shows SpO2 and CO2 (optional) waveforms in real time.
  • Integrated barcode scanner for quick patient ID entry.
  • On-board USB and LAN/serial data ports allow clinicians to easily export data.
  • Optional — Microstream CO2 for intubated and non-intubated patients.

Specifications

General

  • Patient Type: Adult/Pediatric/Neonatal
  • Battery: Internal lithium ion 10.8 to 11.1 V. Operating time: 6 hours with continuous SpO₂ measurements every 4 hours V/mAhr/hours
  • Data Output: HL7 format via Ethernet port. USB port. Optional serial interface adapter
  • Display Modes: large numeric display numeric and waveform display tabular trend display graphical trend display
  • Recorder Type (optional): Paper width: 58mm Speed: 6.25mm, 12.5mm, 25mm, and 50mm/sec; user selectable

Dimensions

  • Width: 10.2 in (26 cm)
  • Height: 3.5 in (9 cm)
  • Depth: 9.1 in (23 cm)
  • Weight (with CO2 and recorder): 4 lbs (1.82 kg)
  • Screen: WQVGA TFT-AM LCD Display | 4.3 in (10.9 cm)

Monitoring Parameters

  • SPO2: Measurement Range: 0 to 100 Accuracy depends on sensor. Heart rate measurement range: 30 to 300 bpm. Heart rate accuracy ± 2% or ± 1 bpm whichever is greater. Complies with EN ISO 9919 standard %
  • CO2 (optional): Microstream technology. Measurement range: 0 to 150 mmHg.Accuracy: 0 - 38 mmHg, ± 2 mmHg. 39 - 99 mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) 100 - 150 ± mmHg, ± 5% of reading (+ 0.08% for every 1 mmHg above 38 mmHg) mmHg
  • Respiration Measurement: 0-150 Rpm
  • Respiration Accuracy: ±1rpm in the range of 0-70rpm ±2rpm in the range of 71-120rpm ±3rpm in the range of 121-150rpm Rpm