Shares same touchscreen controls as other Ultraview Care Network™ and PCMS™ monitors of appropriate levels
Compatible with the full line of Ultraview Care Network and PCMS modules
Large, 10.4-inch (26.42 cm), TFT color display with 140° viewing angle
Data Shuttle® option allows up to 24 hours of patient data to be transferred to other Ultraview Care Network and PCMS monitors
Advanced power management system maximizes battery performance during transport; includes battery "fuel-gauge"
Optional interactive bed-to-bed Ethernet communication
Instant "Quicknet" 10BaseT Ethernet connection
Optional wireless Ethernet with one to five outbound waveforms and numeric vital signs transmitted at 2.4 GHz
Optional built-in 2-channel recorder
Optional mainstream EtCO2, O2, and Min CO2
Support for up to 250 nodes on a network with the Expanded Network feature.
Specifications
Physical Weight & Dimensions
Height: 8.3 inches (21.1 cm)
Depth: 6.2 inches (15.8 cm)
Width: 11.7 inches (29.7 cm)
Weight: 10.0 Ibs (4.6 kg)
General
Touchscreen: With the exception of power (ON/OFF), all controls are on-screen touchkeys; touch is sensed by infrared optical devices; optional controls include mouse and keyboard
Waveform Capacity: four, five, or six waveforms
Module Capacity: 90369 accepts one Ultraview or PCMS module internally and will support up to two additional modules using the 90499 module housing
Parameter Capacity: 18 parameters utilizing Ultraview and PCMS modules as well as Flexport® interfaces
Trends: 24 hours of trend data can be displayed
Graphic: 1-, 2-, 6-,12- or 24-hour segments; data is stored in 1-minute resolutions (6-hour segment is the default)
Tabular: Time increments of 1, 5, 10, 15, or 30 minutes; 1, 1.5 or 3 hours (1 hour is the default)
Remote View/Alarm Watch: When equipped with the Ethernet option, the 1050 provides a waveform display from a remote bedside or telemetry patient on the Ultraview network either on request (Remote View) and/or in response to an alarm (Alarm Watch); the 1050 provides a waveform display from up to 32 selected beds; an Ultraview bedside monitor can be remotely viewed by up to 16 network devices simultaneously (e.g., monitors, workstations)
Electrical
Mains Power: Line voltage: 100-240 VAC; Frequency: 50-60 Hz
Batteries: Both sealed-lead acid (SLA) and Spacelabs Medical nickel metal hydride (NiMH) are supported. One or two 12 V (2.30 Ah SLA or 2.45 Ah NiMH) batteries may be used, providing up to 2.0 hours of operation (TFT display) for up to 300 charge/discharge cycles with SLA and up to 2.5 hours of operation (TFT display) for up to 600 charge/discharge cycles with NiMH; operating time is dependent on configuration and usage; 1.5 hours are required to charge batteries to 100% of capacity with AC connected to rear panel and mains switch in the OFF position, 3-hour charge time required with the mains switch in the ON position
Power Fail Backup: Will maintain patient data for a minimum of three minutes
Isolation: Chassis leakage current not greater than 300 ìA (meets AAMI, UL2601-1, CSA #601.1 and IEC 601-1 standards)